                    Product Details:
 Payment & Shipping Terms:
  | 
                            
| NE40E-X16A: | Chassis | 
|---|
Overview
| 
			 Product Type  | 
			
			 Description  | 
			
			 BOM  | 
			
			 Model  | 
			
			 Earliest Software Version  | 
		
|---|---|---|---|---|
| NE40E-X16A DC | NE40E-X16A Integrated DC Chassis Components(Including 4 Fan Tray) | 02359914 | CR5B0BKP1673 | V800R006C20 | 
| NE40E-X16A AC | NE40E-X16A Integrated AC Chassis Components(Including 4 Fan Tray) | 02359915 | CR5B0BKP1674 | V800R006C20 | 
| NE40E-X16A HVDC | NE40E-X16A Integrated HVDC Chassis Components(Including 4 Fan Tray) | 02351CBD | CR5B0BKP1675 | V800R009C10 | 
| NE40E-X16A DC (2T) | NE40E-X16A Integrated DC Chassis Components(2T,Including 6 Fan Tray) | 02351PJP | CR5B0BKP1676 | V800R010C00 | 
| NE40E-X16A AC (2T) | NE40E-X16A Integrated AC Chassis Components(2T,Including 6 Fan Tray) | 02351PJQ | CR5B0BKP1677 | V800R010C00 | 
| NE40E-X16A HVDC (2T) | NE40E-X16A Integrated HVDC Chassis Components(2T,Including 6 Fan Tray) | 02351PJR | CR5B0BKP1678 | V800R010C00 | 
![]()
![]()
![]()
| 1. Air intake frame (Air Filter) | 2. Mounting ear | 3. ESD jack (front) | 4. Air intake vent in the SFU area | 5. Handle | 
| 6. Power module cover | 7. Power module (PM) | 8. Power monitoring module (PMU) | 9. Switch module | 10. MPU | 
| 11. Cable tray | 12. Cable guide for switch and fabric units (SFUs) | 13. SFU | 14. LPU | 
			 15. Power entry module (PEM)
			 
			NOTE:
			 
			An AC PEM is used as an example here. The DC PEM is also supported. 
			 | 
		
| 16. Fan Module | 17. Air filter | 18. Ground terminal | 19. Non-lifting handle | 20. ESD jack (rear) | 
| 
			 21. Noise Reduction Module
			 
			NOTE:
			 
			Using only the 2T chassis. 
			 | 
			
| 
			 Slot Name  | 
			
			 Slot Quantity  | 
			
			 Slot ID  | 
			
			 Remarks  | 
		
|---|---|---|---|
| LPU | 16 | 1 to 16 | These slots hold LPUs. | 
| MPU | 2 | 17 to 18 | These slots hold MPUs. | 
| SFU | 4 | 19 to 22 | These slots hold SFUs. | 
| Item | 
			 Specification  | 
		
|---|---|
| Dimensions (H x W x D) | 
			
  | 
		
| Weight (empty) | 
			
  | 
		
| Weight (full configuration) | 
			
  | 
		
| Cabinet installation standard | 
			
  | 
		
| Typical power consumption | 
			
  | 
		
| Typical heat dissipation | 
			
  | 
		
| DC input voltage | 
			
  | 
		
| AC input voltage | 
			
  | 
		
| HVDC input voltage | 
			
  | 
		
| MTBF | 22.33 years | 
| MTTR | 0.5 hours | 
| Availability | 0.9999974444 | 
| Slot quantity | 22 | 
| Redundant MPUs | 1:1 | 
| Redundant Switch fabrics | 3+1 | 
| Redundant fans | 
			
  | 
		
| Redundant power supply | 
			
  | 
		
| Forwarding performance | 5600 Mpps (LPUF-240) | 
| Switching capacity | 
			
  | 
		
| Operating temperature | 
			
  | 
		
| Storage temperature | –40°C to +70°C (–40°F to +158°F) | 
| Relative operating humidity | 
			
  | 
		
| Relative storage humidity | 5% to 95% RH, non-condensing | 
| Long-term operating altitude | <= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].) | 
| Storage altitude | Less than 5000 m (16404 ft.) | 